Built-in Limit Switch Linear Actuator
Model:KT1359
Voltage:DC12V
Stroke:10/15/20/25/30/50/75/100mm
Products Description
Built-in limit switch linear actuator KT1359 handles both end positions inside its own tube. When the rod reaches full retraction or full extension, the internal mechanical limit cuts the motor, and the cover it drives stops in the same place on every cycle.
Stroke sets the size first; force sets which version. The 30 N version runs at 30 mm/s no-load and 18 mm/s full-load, which suits a light acrylic or polycarbonate flap that has to open in about a second. The 80 N version runs at 8 mm/s no-load and 5 mm/s full-load, which suits an aluminium guard, a hinged lid carrying instruments or wiring, or any cover where closing force matters more than speed.
The two ends are the stainless front ear and the aluminium tube. Once mounted, the rod travels in a straight line and carries no side load.
Specifications
| Item | KT1359 |
|---|---|
| Type | Miniature electric linear actuator, built-in limit |
| Model | KT1359 |
| Rated voltage | 12 V DC |
| Standard strokes | 10 / 15 / 20 / 25 / 30 / 50 / 75 / 100 mm |
| Outer tube diameter | 13.5 mm |
| Inner rod diameter | 9 mm |
| 30 N version | 3 kg (30 N), 30 mm/s no-load, 18 mm/s full-load |
| 80 N version | 8 kg (80 N), 8 mm/s no-load, 5 mm/s full-load |
| End-of-travel protection | Built-in mechanical limit, auto stop at both ends |
| Self-locking force | Greater than the rated pull force |
| Duty cycle | 10% |
| Operating temperature | -20℃ to 65℃ |
| Front ear / guide sleeve | Stainless steel |
| Outer tube | Aluminium |
| Housing | Nylon |
| Drive components | Copper alloy |
Application Fields
- Weighing and metering equipment. Draft shields and sliding doors on bench scales, price-computing scales and weighing terminals. Short strokes, repeatable stop position.
- Office and printing equipment. Media lids and hatches on label printers and desktop terminals. Light covers, frequent opening.
- Test jigs and production line equipment. Probe guard doors and packaging machine flap gates. Stop on arrival without using space inside the frame.
- Commercial and display equipment. Coffee machine hopper slides and display case glass hood lifts. Thin frames, two positions only.
Typical devices for each stroke are listed in the selection table below. Stroke comes from the opening height: a short step to crack open, a long step to move clear. Laboratory and inspection instrument cases are under laboratory equipment actuators; other devices are on our applications page.
Built-in Limit vs External limit protection Board

External limit protection Board
An actuator with an external limit board adds a board outside the tube, and that board does two jobs: end-of-travel stop and overload protection. The cost is space - the board sits outside the tube, the cover frame has to carry two switch positions, and assembly gains a fixing step.
Built-in Limit
Built-in limit KT1359 has a mechanical limit only: the motor is cut at both ends, and there is no overload protection. What it saves is space - the mechanism sits inside the tube, the internal clearance of the cover stays as designed, and one or two assembly steps drop out.

Selection by Stroke
| Stroke | 30 N version, no-load / full-load | 80 N version, no-load / full-load |
|---|---|---|
| 10 mm | 0.3 s / 0.6 s | 1.3 s / 2.0 s |
| 15 mm | 0.5 s / 0.8 s | 1.9 s / 3.0 s |
| 20 mm | 0.7 s / 1.1 s | 2.5 s / 4.0 s |
| 25 mm | 0.8 s / 1.4 s | 3.1 s / 5.0 s |
| 30 mm | 1.0 s / 1.7 s | 3.8 s / 6.0 s |
| 50 mm | 1.7 s / 2.8 s | 6.3 s / 10.0 s |
| 75 mm | 2.5 s / 4.2 s | 9.4 s / 15.0 s |
| 100 mm | 3.3 s / 5.6 s | 12.5 s / 20.0 s |
Force is estimated as a moment: force ≈ cover weight x centre-of-gravity distance to the hinge / perpendicular distance from the hinge to the actuator. A 1 kg flap with its centre of gravity 150 mm from the hinge, driven 100 mm from the hinge, needs about 15 N, which leaves the 30 N version a 2x margin; the same geometry at 2 kg needs 30 N and is carried by the 80 N version. Most devices in the table are covers of about 1 kg, so either version drives them and the choice comes down to speed and closing force.
Cycle Time and 10% Duty
A 10% duty cycle means powered running time is at most one tenth of the full cycle. Take the 80 N version at 100 mm and 20 s full-load: the full cycle must be at least 200 s, so 180 s of rest sits between two movements. The 30 N version moves in about a second, which leaves more duty headroom, but continuous reciprocation is still outside the rating.
Auto stop at both ends helps the cycle calculation: while the cover sits open or closed the motor is already cut, so that dwell counts as off-time. Open, pause, close, pause fits inside the 10% duty cycle; back-and-forth without a pause does not.
Factory, Testing and Certification
A functional test is carried out before packing; the benches used for those checks are listed under testing equipment. The quality system is ISO 9001:2015 and the product carries CE, RoHS, CCC and TUV, shown on our certification page.
Company and inspection capability are on about us and why us.
frequently answer question

01.Does KT1359 need an external limit board?
02.What happens if the cover is blocked mid-stroke?
03.30N or 80N?
04.Can it reciprocate continuously inside a test cycle?
05.Which strokes are standard?
Ordering
Send the request through contact. Please include: stroke, version (30 N or 80 N), quantity, and the date you need the first batch. Attach the mounting drawing if you want the fit checked.