Dc Brush Electric Actuator
video

Dc Brush Electric Actuator

DC brush electric actuator KT0805-50H delivers 50 mm of push-pull travel from a 116.5 mm body on 5 V DC at 0.2 A. A brushed motor drives a copper alloy screw inside an 8 mm 304 stainless steel tube, moving a 5 mm rod at 9 mm/s free-running and 6 mm/s once the full 0.3 kg is behind it, and the screw holds 100 N once the current stops. Travel is built to order between 30 mm and 120 mm, the front connector unscrews for a different end fitting, and the body is sealed to IP56.
Send Inquiry
Product Introduction

 

DC brush electric actuator KT0805-50H

 

tem Value
Model KT0805-50H
Version Fast build, speed priority, 0.3 kg rated load
Supply 5 V DC, 0.2 A protection current, about 1 W
Stroke 50 mm standard
Stroke range 30 / 50 / 80 / 100 / 120 mm in the same tube; other lengths to drawing
Retracted length 116.5 mm
Extended length 166.5 mm
Push-pull force 0.3 kg / 3 N, held to the end of the stroke
Speed, free-running 9 mm/s, 5.6 s for the full 50 mm
Speed at rated load 6 mm/s, 8.3 s for the full 50 mm
Holding force 100 N / 10 kg with no current applied
Duty cycle 10%, six seconds running per minute
Noise ≤50 dB
Sealing IP56, dust protected, resistant to water jets
Tube and rod 8 mm outer tube, 5 mm rod, 304 stainless steel
Screw Copper alloy
Head 7 mm, two 3 mm holes, detachable
Head thread M3 internal, 5 mm deep; M4 or M5 to order
Tube thread M9 external, to order
End of stroke Automatic stop at both ends
Limit protection External board, mounted on the outside of the tube
Position feedback None fitted; no encoder, no position output
Mounting Any orientation, with the load guided along the rod
Warranty 6 months or 10,000 cycles, whichever comes first
Customization Stroke, head thread, tube thread, head style, lead length

 

Sample Load Port Shutter

 

The mechanism this build was sized around is the load port of a bench-top sample preparation instrument. An operator slides a rack of vials through a front aperture roughly 40 mm high, a shutter closes, and the run starts; the shutter holds dust, ambient light and hands out of the sample compartment until the run ends. The shutter is 180 g of anodised aluminium on two short rails, with a soft gasket at the closed end.

  • 40 mm of aperture, 50 mm of travel. The extra 10 mm is the part that matters: the shutter edge clears the last vial cap in the rack, and the open position parks behind the aperture instead of half across it, so a cap cannot catch on the way in.
  • 3 N against a load of about 2 N. One hundred and eighty grams on dry rails costs under 1 N to slide, and the gasket adds about half a newton at the closed end. What is left absorbs a rail that has collected dust for a year of bench use, and 6 mm/s under load still clears the port in 8.3 s - inside a load sequence that waits for the operator anyway.
  • 100 N of hold with the instrument switched off. A rack left leaning against the shutter, a cloth during cleaning, a bench knocked in transit: none of these pushes a screw back. No coil stays warm to keep the port shut, which matters when the instrument sits powered down overnight between runs.
  • 116.5 mm of body in a 42 mm channel. Motor and screw take most of the length, and the limit board adds a step of its own outside the tube, so a cradle cut as a plain cylinder pinches the board and stops the shutter in the wrong place. The M9 tube thread is the cleaner answer where the panel already has a boss.
  • Fixed stops, the same seat every cycle. Both ends are set by the external board, so the shutter meets its gasket at the same point on the ten-thousandth cycle as on the first, with no homing move at start-up and no drift into the aperture as the rails wear.

 

What the mechanism needs What this build provides
Clear a 40 mm aperture with margin 50 mm of travel
Shift 180 g on two rails, gasket at the closed end 3 N, 6 mm/s under load
Port shut with the instrument unplugged 100 N holding, no current drawn
42 mm channel beside the sample compartment 116.5 mm body, 8 mm tube
Run from the instrument's logic rail 5 V DC at 0.2 A, about 1 W
Bench shared with two other instruments ≤50 dB
Wipe-down between runs IP56 on 304 stainless steel

 

The same arrangement covers lids, trays and low-frequency shields across laboratory instruments. Those cases sit together on the laboratory equipment page, and the other openings this family drives are grouped on the applications hub.

 

Load Budget

Whether 3 N covers a mechanism is arithmetic, and it is short enough to finish before the drawing is. The worked example below is the 180 g shutter from the section above, sliding horizontally on two dry rails.

 

Item Assumption Force at the rod
Shutter weight 180 g on a horizontal slide 1.77 N normal load
Rail friction μ = 0.15, dry polymer wheel on aluminium 0.27 N
Gasket preload soft closed-cell strip, 40 mm contact length 0.50 N
Lead drag clipped pair, no return spring 0.20 N
Total to move   0.97 N
Rating 0.3 kg / 3 N, held to the end of the stroke 3.1× margin

That margin is what a bench instrument spends over its life: dust on the rails raises μ, a gasket takes a set and needs more push, a rail aligned once is never aligned again. A drive sized to the clean-bench figure has nothing left for any of it.

Two changes move the total fastest. A vertical lift carries the whole 1.77 N of weight instead of the fraction that friction sees, which brings the total to 2.74 N and leaves 0.26 N in hand. A gasket compressed 2 mm rather than a soft strip can add around 2 N by itself, and that is the point where the 2 kg build takes over.

Measured figures replace the assumptions one for one, and a spring scale hooked to the shutter in its own chassis measures them faster than any calculation.

 

What It Replaces

 

The comparison worth making is between arrangements rather than between brands, because a solenoid from one supplier and a solenoid from another obey the same physics. Two arrangements usually sit where this build goes: a solenoid with a return spring, and a stepper driving the shutter through a coupling.

 

Requirement Spring-return solenoid Stepper with coupling KT0805-50H
Port stays shut with no current ✗ the spring decides; held only while energised △ detent holds it, driver stays powered ✓ 100 N from the screw
Same seat on every cycle ✗ bumper compression varies △ repeatable once homed ✓ stops set mechanically
Travel matched to a 40 mm aperture ✗ one coil, one throw ✓ programmable ✓ built at 50 mm
Envelope under 120 mm ✓ ✗ motor, coupling, driver board ✓ 116.5 mm
Runs from the logic rail △ coil current needs a switching stage ✗ needs a driver stage ✓ 0.2 A at 5 V
Nothing to home at start-up ✓ ✗ home switch and a move to find it ✓
Audible on a shared bench ✗ steel against steel at both ends △ gear whine ✓ ≤50 dB

 

What a buyer notices is not the table but its consequences: a change of stroke is a line on the production order instead of a new coil, there is no driver board to find space for beside the mechanism, and the closed position does not depend on a spring that has been compressed ten thousand times. What the arrangement gives up is a snap - 5.6 s for the full 50 mm is slower than a solenoid closing and faster than most geared steppers asked to shift the same shutter.

 

Model Selection

 

Five members of the range sit close enough to be confused on a drawing. Travel, force and retracted length are the three figures that separate them, and the fourth - holding force - is the same on all five.

 

Requirement KT0905-15H KT0805-30H KT0805-50H KT0805-50L KT0805-80L
50 mm of travel ✗ 15 mm ✗ 30 mm ✓ ✓ ✗ 80 mm
Port clear in under 10 s ✓ 1.7 s ✓ 3.3 s ✓ 5.6 s ✗ 25 s ✗ 40 s
Moving part under 0.25 kg ✓ ✓ ✓ △ over-specified △ over-specified
Guide or gasket above 0.5 kg ✗ 0.3 kg ✗ 0.3 kg ✗ 0.3 kg ✓ 2 kg ✓ 2 kg
Body 120 mm or shorter ✓ 69 mm ✓ 96.5 mm ✓ 116.5 mm ✓ 116.5 mm ✗ 146.5 mm
Held with the supply off ✓ ✓ ✓ ✓ ✓
5 V DC at 0.2 A ✓ ✓ ✓ ✓ ✓

 

The 15H and 30H answer a smaller aperture in a tighter channel, and the tiny linear actuator page covers the shorter strokes in another tube. The 50L and 80L answer a moving part that carries gasket preload or runs on a stiff guide. Inside 50 mm of travel with a light part, the decision is between the two 50 mm builds, and the only question left is how much force the mechanism costs.

 

 

Mounting and Clearance

 

  • Side load belongs to the rails. Force across a 5 mm rod shows up as a bow, and a bow ends up in the screw. A pair of short rails, or a slide under the tray, absorbs the force of a hand or a misloaded rack, leaving the rod with nothing to do but push straight. Where the shutter has no guide of its own, a pair of pins in the chassis is cheaper than a heavier actuator.
  • The limit board is a step, not a cylinder. It sits outside the 8 mm tube, so the body is wider than the tube at that point. A cradle bored for 8 mm will pinch the board; leave the step open, or use the M9 thread on the tube and lock it through the panel with a nut.
  • Any orientation, rod up or down. The unit mounts in any position, including rod down, because the screw holds the load either way. With the rod pointing up, a drip edge above the rod exit keeps whatever falls onto the panel away from the seal.
  • Leads exit at the body end. The pair leaves the housing behind the limit board, so the channel has to carry the lead bend as well as the body. Cut leads to the harness length at order rather than coiling the surplus inside a 42 mm channel, where it sits against the rod.

 

Quality Control and Certificates

 

Every unit runs to both stops before packing, under an ISO9001:2015 system whose checks begin with incoming material: tube and rod dimensions, motor current and speed, insulation and electrical tests, salt spray on the stainless guide, and wire bending at the lead exit. The salt spray step stays in even though this build is sold into dry equipment, because it is the check that the 8 mm tube needs no plating to stay clean at the rod exit. CE and RoHS documentation is held for the range: current certificates sit on the certification page, the gauges and rigs used in those tests appear under testing equipment, and the plant, its history and the route a batch follows are set out on about us and why us.

 

Frequently Asked Questions

Q: Does the instrument need a switch to know the shutter is closed?

A: Not on the rod. Both stops are set mechanically by the external board, so the closed position repeats without a sensor on the drive, and the instrument sequences the movement by time - 5.6 s free-running, 8.3 s at the rated load, with a second of margin either way. Where the machine confirms the position for safety, that switch goes on the shutter; the drive carries no encoder and no position output.

Q: Are the brushes the part that wears out first?

A: They are, and no separate brush life is published for this motor. What is published is 10,000 cycles or six months, whichever comes first, and that is the figure to build a service interval around. At the 10% duty limit the drive runs about 30 cycles an hour, which reaches that ceiling within a few weeks of continuous shifts - so a mechanism planned at that rate is worth reviewing before the chassis is tooled.

Q: What happens if a rack jams against the shutter?

A: The screw holds 100 N, and a jam above that pushes the drive back and can force travel past a stop. The board ends the stroke at each end, and the screw holds the closed position at 100 N. The 0.2 A is the rated protection current, about 1 W at the figures in the table.

Q: Will vibration on a shared bench move the shutter?

A: Not through the drive. One hundred newtons of holding force is far above anything a bench, a pump or a centrifuge passes through a frame, and the screw has to be back-driven for the shutter to shift. Play in worn rails is a separate matter: the shutter can rattle within that play while the rod stays where it was left, and the cure is a rail or a new gasket, not a stronger drive.

Q: Can the port be wiped with 70% IPA, or survive a spill?

A: A wipe, yes. IP56 covers dust and water jets on a 304 tube and a 5 mm rod that carries no plating to wear through. A spill is a different case: the seal is a wear item, and the rating assumes water leaves the rod exit rather than sits on it, so a tray beneath the mechanism or a drip edge above it keeps the seal working for its full life.

Q: How often can the port open and close in a run cycle?

A: One open-and-close at 50 mm takes about 11 s free-running, so the 10% duty allows roughly one cycle every two minutes, or thirty an hour. An instrument injecting every 15 to 30 minutes sits well inside that with the margin to spare for a re-run. A rack loaded every 90 s sits on the limit, and a faster mechanism is quoted against its measured cycle rate.

Q: Which thread should the drawing specify?

A: The one the bracket already has. M3 internal to 5 mm is standard, M4 and M5 are cut to order, and M9 external on the tube suits a panel boss or a locknut where a cradle will not fit. The 7 mm head unscrews, so a machine that already uses a stud or a clamp block takes the same rod without a new end, and changing the end fitting does not disturb the stroke.

 

 

 

Hot Tags: dc brush electric actuator, China dc brush electric actuator manufacturers, suppliers, factory, compact electric actuator, electric motor valve, 12 electric actuator, orbit actuator, mechanical actuators, 600 lb linear actuator

Send Inquiry

whatsapp

Phone

E-mail

Inquiry